global medical manufacturer since 1973 over 45 years strong

Neonatal Skin Temperature Sensor Probes

  • Provides comfortable and precise management of neonatal patients’ vital signs.
  • Compatible with the most common neonatal temperature monitoring and warming equipment.
  • Available in a one-piece completely disposable design (HNICU series probes) or through a connecting interface cable (FNICU series probes).
  • Unique color-coding system ensures proper sensor identification during use and storage.
  • Reflective sensor cover deflects radiant heat for more accurate readings.
  • Disposable replacement pads available in choice of hydrogel or adhesive pads to adhere to fragile infant skin without irritation.
  • Packaged 50 probes per case.
  • Interface cable is 3ft (0.91m) in length
INDICATIONS
Product No.ColorProbe CoverMachines and ManufacturersReplaces Probe Number
HNICU-22 (Disposable Probe) Black Cover Hydrogel Probe w/Foam ⅞"Ohmeda®/Care Plus Intensive Care Incubaor NIC, Infant Warmer System (IWS) 3000, 3300, 3500, 5000Ohmeda® LA001, OEM #LA003, LA005, #6600-0196-700 #6600-0208-700, Level 1's STS-203
HNICU-25 (Disposable Probe) PurpleCover Acrylic w/Foam ⅞"Air-Shields® Isolette® C100, C450, C550, IT500, C200, PM72s, PM78s & Radiant Warmers IICS, IICS90, IICS-VHA, BRW, DRW & ESIW 20C550 Air-Shields®/Vicker's 68-209-70 Level 1's STS-201
HNICU-26 (Disposable Probe) Orange Cover Hydrogel w/o Foam ⅞"Ohmeda®/Care Plus Intensive Care IC, GC and CP Incubator & Infant Warmer System (IWS) 2001, 3000, 3300, 3500, & 5000Ohmeda® LA003 (Reusable) & LA005 (Disposable) #6600-0196-700 #6600-0208-700 Level 1's STS-204
HNICU-29 (Disposable Probe) Green Cover Acrylic w/Foam ⅞"Air-Shields® C86 Incubator (Old Version) & Infant Radiant Warmers System ICS & Mobile Infant Warmers Air-Shields®/Vicker's 17-575-14
HNICU-30 (Disposable Probe) BlueCover Hydrogel Probe w/Foam ⅞"Hill-Rom® Stabilet Radiant Warmers 1200 Series, 1500 Series & 2000CCareFusion® 10-1910-020, 10-1910-060, Hill-Rom® BCZ009, Level 1's STS-206
HNICU-31 (Disposable Probe) GoldCover Hydrogel Probe w/Foam ⅞"Hill-Rom® Stabilet Radiant Warmers 200 & 2000 Series, Drager® Isolette® Incubators/C-100, C450, C550, and PM-78 Radiant Warmers CareFusion® OEM, Preemie Probe 1, #68-209-20/MUO6933, #68-209-30/MUO6935, 10-1910-020, 10-1910-060 Hill-Rom® BCZ008 Level 1's STS-205
HNICU-32 (Disposable Probe) BlueCover Hydrogel Probe w/Foam ⅞"Drager® Babytherm® 8010, 8000, Overhead Radiant Heater 2M20116, Incubators 8000 IC & 8000 SC (Standard Care) Drager® Reusable Probe 8405371
HNICU-33 (Disposable Probe) YellowCover Hydrogel Probe w/Foam ⅞"Drager® Isolette® 8000 IC w/Thermo Monitoring, Babytherm® 8004, & Babytherm® 8010No Reusable by Drager®
HNICU-34 (Disposable Probe) WhiteCover Hydrogel Probe w/Foam ⅞"Drager® Babytherm® 8004 & Babytherm® 8010No Reusable by Drager®
HNICU-35 (Disposable Probe) Green Cover Hydrogel w/F 1⅛”Air-Shields® Isolette® C100, C400QT, C450QT, C550, IT500, & Radiant Warmer IICS-90 Resuscitaire® PM-78 Radiant Warmers CareFusion® OEM, Preemie Probe 3, #81-300-006, #81-300-008 MU11228, #81-300-009/MU11229, 10-1910-020, 10-1910-060, Air Shields® 81-300-05, 81-300-08, & 81-300-09
HNICU-36 (Disposable Probe) Putty Cover Hydrogel Temperature Skin Senso w/o Foam ⅞"Drager® Isolette® C2000 & 8000 Incubators, Versalet 7700 Care Center Drager® M911228-02 Preemie Probe 5-5-L #83-104-15/MU12551
HNICU-37 (Disposable Probe) Putty Cover Hydrogel Temperature Skin Senso w/o Foam ⅞"GE® Giraffe OmniBed, Giraffe Incubators, Giraffe Warmers & Panda Warmers "CareFusion® 10-1910-020, 10-1910-060 GE® 6600-0873-700 & 6600-0874-700 Level 1's STS-209"
HNICU-38 (Disposable Probe) YellowCover Acrylic w/Foam ⅞"Drager® Babytherm® 8004 & Babytherm® 8010 CALEO IncubatorsCareFusion® OEM, MX11000, 10-1910-010, 10-1910-060 No Reusable by Drager®
HNICU-39 (Disposable Probe) YellowCover Hydrogel w/o Fm 1⅛"ATOM® Infa Warmer 1® ATOM® Medical Incubators Skin Temp Probe 1 NT-024 Reusable Yellow 60881 Reusable White, OEM Nf-023, NF-024 #60882, #60883, #60084 w/connector

 

Reusable Interface
Product No.ColorProbe CoverMachines and ManufacturersReplaces Probe Number
NI-25
(Reusable Cable)
Purple n/aAir-Shields® Isolette® C100, C450, C550, IT500, C200, PM72s, & Radiant Warmers IICS, IICS90, IICS-VHA, BRW, DRW & ESIW 20C550, PM78s Air-Shields®/Vicker’s 68-209-70 Level 1’s STS-201
FNICU-25 (Disposable Probe) PurpleCover Hydrogel w/o Foam ⅞”Air-Shields® Isolette® C100, C450, C550, IT500, C200, PM72s, & Radiant Warmers IICS, IICS90, IICS-VHA, BRW, DRW & ESIW 20C550, PM78s Air-Shields®/Vicker’s 68-209-70 Level 1’s STS-201
NI-26
(Reusable Cable)
Orange n/aOhmeda®/Care Plus Intensive Care IC, GC and CP Incubator & Infant Warmer System (IWS) 2001, 3000, 3300, 3500, & 5000Ohmeda® LA003 (Reusable) & LA005 (Disposable) #6600-0196-700 #6600-0208-700 Level 1’s STS-204
FNICU-26 (Disposable Probe) Orange Cover Hydrogel w/o Foam ⅞”Ohmeda®/Care Plus Intensive Care IC, GC and CP Incubator & Infant Warmer System (IWS) 2001, 3000, 3300, 3500, & 5000Ohmeda® LA003 (Reusable) & LA005 (Disposable) #6600-0196-700 #6600-0208-700 Level 1’s STS-204
NI-35
(Reusable Cable)
Greenn/aAir-Shields® Isolette® C100, C400QT, C450QT, C550, IT500, & Radiant Warmer IICS-90 Resuscitaire® PM-78 Radiant Warmers CareFusion® OEM, Preemie Probe 3, #81-300-006, #81-300-008 MU11228, #81-300-009/MU11229, 10-1910-020, 10-1910-060, Air Shields® 81-300-05, 81-300-08, & 81-300-09
FNICU-35 (Disposable Probe) GreenCover Hydrogel w/o Foam ⅞”Air-Shields® Isolette® C100, C400QT, C450QT, C550, IT500, & Radiant Warmer IICS-90 Resuscitaire® PM-78 Radiant Warmers CareFusion® OEM, Preemie Probe 3, #81-300-006, #81-300-008 MU11228, #81-300-009/MU11229, 10-1910-020, 10-1910-060, Air Shields® 81-300-05, 81-300-08, & 81-300-09
NI-36
(Reusable Cable)
Puttyn/aDrager® Isolette® C2000 & 8000 Incubators, Versalet 7700 Care CenterDrager® M911228-02 Preemie Probe 5-5-L #83-104-15/MU12551
FNICU-36 (Disposable Probe) PuttyCover Hydrogel w/o Foam ⅞”Drager® Isolette® C2000 & 8000 Incubators, Versalet 7700 Care CenterDrager® M911228-02 Preemie Probe 5-5-L #83-104-15/MU12551
NI-37
(Reusable Cable)
Puttyn/aGE® Giraffe OmniBed, Giraffe Incubators, Giraffe Warmers & Panda Warmers CareFusion® 10-1910-020, 10-1910-060 GE® 6600-0873-700 & 6600-0874-700 Level 1’s STS-209
FNICU-37 (Disposable Probe) PuttyCover Hydrogel w/o Foam ⅞”GE® Giraffe OmniBed, Giraffe Incubators, Giraffe Warmers & Panda Warmers CareFusion® 10-1910-020, 10-1910-060 GE® 6600-0873-700 & 6600-0874-700 Level 1’s STS-209

Details for Product No. Product number

  • UPN:
  • Sterilization:
  • Latex:
  • HCPCS Code:
  • CE MArk:

Not Registered?

Learn more & sign up for Web Tools today.

The product detail information for this product is not available at this time. Please try again later.

ordering-btn
place
an order
by phone, fax, online or email
automated
inventory
with rfid charge capture
QZ8A1649